Mecer 2000VA On-line Tower UPS
( ME-2000-WPTU )
Overview
Mecer 2000VA Online Tower UPS (ME-2000-WPTU) has a wide input voltage range and an available converter mode.
Features
- True double-conversion online UPS
- Wide input voltage range (110-300 VAC)
- Input power factor correction 0.99
- Output power factor 0.8
- Converter mode available
- ECO mode operation for energy saving (only available for 1-3KVA)
- Generator compatible
- Adjustable battery numbers only available for 6K and up models
- Smart SNMP works well with either USB or RS-232 together
- Emergency power off function only available for 6K and up models
Mecer 2000VA Online Tower UPS
A UPS is not designed to provide continuous power, it allows a computer or device to keep running for a short period of time when the primary power source is lost.
MORE UPS OPTIONS
Specifications
Phase
Single phase with ground
Capacity
2000 VA / 1600 W
Input
Voltage Range
Low Line Transfer
160 VAC / 140 VAC / 120 VAC / 110 VAC ± 5% (Ambient Temp. < 35°C) (based on load percentage 100% – 80% / 80% – 70% / 70-60 % / 60% – 0)
Low Line Comeback
175 VAC / 155 VAC / 135 VAC / 125 VAC ± 5% (Ambient Temp. <35°C) (based on load percentage 100% – 80% / 80% – 70% / 70 – 60% / 60% – 0)
High Line Transfer
300 VAC ± 5%
High Line Comeback
290 VAC ± 5%
Frequency Range
40HZ ~ 70 HZ
Power Factor
≥ 0.99 @ nominal voltage
Output
Output Voltage
200/208/220/230/240 VAC
AC Voltage Regulation (Batt. Mode)
± 1%
Frequency Range (Synchronised Range)
47 ~ 53 Hz or 57 ~ 63 Hz
Frequency Range (Batt. Mode)
50 Hz ± 0.25 Hz or 60 Hz ± 0.3 Hz
Current Crest Ratio
3:1
Harmonic Distortion
≤ 3 % THD (Linear Load), ≤ 6 % THD (non-linear load)
Transfer Time
AC Mode to Batt. Mode
Zero
Inverter to Bypass
4 ms (Typical)
Waveform (Batt. Mode)
Pure Sinewave
Efficiency
AC Mode
89%
Battery Mode
87%
Battery
Battery Type
12 V 9 Ah
Numbers
4
Typical Recharge Time
4 hours to recover to 90% capacity
Charging Current (max.)
1.0 A
Charging Voltage
54.7 VDC ± 1%
Indicators
LCD Panel
UPS status, Load level, Battery level, Input/output Voltage, Discharge timer and Fault Conditions
Alarm
Battery Mode
Sounding every 4 seconds
Low Battery
Sounding every second
Overload
Sounding twice every second
Fault
Continuously sounding
Physical
Dimension, D x W x H (mm)
397 x 145 x 220
Net Weight (kgs)
17
Environment
Humidity
20-90 % RH @ 0-40°C (non-condensing)
Noise Level
Less than 50dB @ 1 Meter
Management
Smart RS-232/USB
Supports Windows® 2000/2003/XP/Vista/2008, Windows® 7/8, Linux, Unix and Mac
Optional SNMP
Power management from SNMP manager and web browser